13
smartCUE Interfaces | User Manual | Control Ports
© CUE, a.s. All Rights Reserved. | www.cuesystem.com | [email protected]
Bi-directional Serial RS-232/422/485
Overview
These bi-directional serial channels are used for RS-232, RS-422 and RS-485 communication.
Baud rate can be set to the following values: 300, 600, 1 200, 2 400, 4 800, 9 600, 19 200, 38 400, 57 600,
115 200, 230 400 and 460 800 Bd (bps).
Default mode for all channels is RS-232, other modes must be set in programming application. For more
details see programming manuals.
RS-232 Mode
Output signal levels for RS-232 are in the -10 V to +10 V range. This is default mode for all channels.
Connector pin out
SERIAL RS-232
5-pin 3.5 mm Pin Signal Description Direction
1 2 3 4 5
1 TxD RS-232 Transmitted Data From interface
2 RTS RS-232 Request to Send From interface
3 GND Ground
4 RxD RS-232 Received Data To interface
5 CTS RS-232 Clear to Send To interface
RS-422 Mode
This mode must be set in the programming application.
Connector pin out
SERIAL RS-422
5-pin 3.5 mm Pin Signal Description Direction
1 2 3 4 5
1 Tx A+ RS-422 Transmit Data (Idles High) From interface
2 Tx B- RS-422 Transmit Data (Idles Low) From interface
3 GND Ground
4 Rx A+ RS-422 Receive Data (Idles High) To interface
5 Rx B- RS-422 Receive Data (Idles Low) To interface
RS-485 Mode
This mode must be set in the programming application.
Connector pin out
SERIAL RS-485
5-pin 3.5 mm Pin Signal Description
1 2 3 4 5
1 A+ RS-422 Transmit Data (Idles High)
2 B- RS-422 Transmit Data (Idles Low)
3 GND Ground
4 N.C. RS-422 Receive Data (Idles High)
5 N.C. RS-422 Receive Data (Idles Low)